Monday, April 25, 2011

Re: [MW:10829] usage of 45 deg elbow cut from 90 deg elbow.

Dear Murthy,
obviously u can cut & use 90 Deg elbow to 45 Deg elbow according to site conditions (if u people are not existing at that time), but after cutting ensure that to make DPT at the bevel ends & lamination (UT) for those bevel ends of ur using 45 Deg Elbow.


With warm Rgds,
Ratnakar Grandhi.

On Sun, Apr 24, 2011 at 4:45 PM, narasimha murthy <jnm71269@gmail.com> wrote:
Dear All,
 
Please suggest if you can cut a 90 deg elbow and use as 45 Deg elbow is it acceptable practice and if so is there any code refered to such usage.
 
Regards,
 
Murthy

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...