Saturday, April 30, 2011

[MW:10892] Diameter of electrode-reg

Dear Experts,
 
               While my routine inspection of welding I have noticed Diameter of the electrode used for the capping was not as per the qualified WPS and I was told the diameter of the electrode is not an essential variables.
 
  WPS for SMAW
 
Now as per the sec IX; Table QW-253
 
1) the essential variable QW-404.30
 
2) Supplementary variables QW-404.7/.12
 
3)  Non essential varaiable QW-404.6
 
       &
as per the QW-353
 
1) QW-404.15/.30 were the essential variables for welder qualification.
 
So if the diameter of electrode used in production welds beyond 6mm then only the WPS
needs to be re written? or Should we insist the welder to use what ever mentioned in the qualified WPS? or the welder should use the electrode that he used while performing his WQT.
Can somebody expain me in details how to deal this?
 
Regards
Ilangkumaran
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...