Thursday, April 28, 2011

[MW:10878] Re: Normalizing of Clad Dish Ends

hi

On Apr 7, 10:19 am, JASPAL SINGH <jaspaldh...@gmail.com> wrote:
> Dear Members,
>
> This is with reference to Normalizing requirement clad dish ends above
> 16mm Thickness.
>
> Is it advisable to go for Normalizing treatment of clad dish end(300
> series clad, Duplex).
>
> As most of the customer ask in the specification that dish end above
> 16mm shall be normalised, can we interpret this that the same is
> applicable for non cladded plates only.
>
> What may be the pros & cons.
>
> Regards
>
> Jaspal Singh
> Quality Assurance
> ISGEC-Yamunanagar
> -9996624244

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...