Tuesday, April 12, 2011

[MW:10655] hydro testing of Pipelines




Team,
 
We have just completed the hydro test for 66" underground Pipeline the temperature at the begining of the test / Holding time was 13 Deg C. and after 14 hrs of the holding period ( 24 hrs ) the temperature was 24 deg C.
 
what will be the change in pressure ?
 
Regards,

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...