yes but not applicable to FCAW and SAW


On Sat, 26 Mar 2011 19:07:28 , Ramesh Barot <rameshnbarot@yahoo.com> wrote
Dear experts,
 
same to be applicable for GTAW? means three times of filler wire dia? if not please give the reason.
 
Thanks,
With Best Regards,
Ramesh Barot



From: Muhammed Ibrahim PK <ibratech@gmail.com>
To: materials-welding@googlegroups.com
Sent: Thu, March 24, 2011 10:28:58 PM
Subject: Re: [MW:10483] Weaving

Hi,
 
If the job is in low temperature service we have to strictly control it. In other cases it will not make serious issue. But as a good engineering practice, reduce the weaving to 3 times of electrode dia max.

Thanks & Regards
Muhammed Ibrahim PK



On 24 March 2011 10:31, Sampath Kumar <skthatham@gmail.com" >skthatham@gmail.com> wrote:
Dear Friends,
 
WPS says the weaving is allowed/permitted 3times the diameter of the electrode.Please tell me wheather we can allow if the weaving is more than the allowable limit.If it can be allowed.What is the reasons and on what basis it is allowed?If it can not/should not be allowed.Why and what is the reasons?
 
My opinion is that it should not be allowed.[1]Because it deviates from the WPS.[2]properties may vary because of the excess heat In put due to excess weaving.
 
The contractor is of opinion that they will change the WPS to suit excess weaving.It is not an essential variable,hence it can be allowed.To substantiate their claim they say they will change the WPS and they will perform Hardness Test to prove that the properties were not changed.
With Best Regards
Sampath
 
 

--
To post to this group, send email to materials-welding@googlegroups.com" >materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding%2Bunsubscribe@googlegroups.com" >materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...