Re: [MW:10322] Welding of S355JO with ST52-3

Dear HA,
 
This job must be only structural welding.  PWHT may not be required if thickness is less than 38 mm.   E 7018 is best choise and as per structural welding code you can use one level iow strength than base metal can used for better fatigue strength.
PWHT may be required only incase dimensional stability ( machining is required after welding)


 
On Sun, Mar 13, 2011 at 11:19 AM, hany alfy <hanyon_alfy@yahoo.com> wrote:
Dear Experts,
 
Can you please advice which electorde we can use for Welding of S355JO with ST52-3
 
Also if there is any pre-heat or PWHT had to be applied
 
Regards,
H.A



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...