Friday, March 4, 2011

Re: [MW:10128] preparation of wps for c.s. or s.s.

Dear Shankar,
 
You want to weld on dissimilar materials  ? or each Grade separate. which electrodes you are using and position,and what is the purpose Example: Using for process piping, structural work etc.....
 
What kind of welding process you are using, FCAW,GTAW,SMAW? so that electrical parameters can be identified. exactly on which thickness you are going to test (PQR). according that range can be decided
 
Yes in the section IX it was mentioned, it is only meant for welding and welding qualifications
 
Regards

 
On Thu, Mar 3, 2011 at 9:07 PM, shankar k <shankark.qc@gmail.com> wrote:
can anybody explain "how to prepare WPS for CS(A106 Gr.B for example) or SS(A304) , which codes we have to refer in ASME sec ix?
take the material thickness range 3.6mm to 10mm
 
 
thanks,
shankar.k
qc inspector
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--

Thanks & Regards
 

QA&QC Manager

Dome OMV Al Uqlah CPF Construction Project,

Dome Trading & Contracting Co.Ltd,
Villa # 18, Street # 38 (off Hadda Road)
P.O.Box : 16187,
Sana'a, Republic of Yemen.
Tel : 00967 1 414023, EXTN: 121,
Mobile : 00967 714701407
Web Site:
www.domeint.com

 


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...