[MW:10225] Re: Filler metal Test like.. chemical, impact, al weld tensile is mandatory requirement or not As per ASME SEC 2 C, when qualifying WPS by AWS D1.1?

Hi sir,

As from ur words,
The test requirements as per ASME sec 2 C is only need for
manfactures / or if mentioned by customer client, we have to go for
those test.

So for WPS qualification just we refer AWS D1.1 is enough.

am i right?
pl comment...

Tnks
Srinivas

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...