Re: [MW:9831] SA 516 Gr.60 high in manganese-accept or reject

Dear Mr.Bathula Raghuram,
As per note C it is not acceptable because the thickness mentioned is 10mm plates so Note C applies,if Iam correct.Pls put your comments also

On Fri, Feb 11, 2011 at 5:14 PM, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote:

Refer the note B of Table 1 in SA516

"For each reduction of 0.01 percentage point below the specified maximum for carton, an increase of 0.06 percentage point above the specified maximum for manganese is permitted, up to a maximum of 1.50% by heat analysis and 1.60% by product analysis".

 

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of krishna
Sent: Friday, February 11, 2011 5:02 PM
To: materialswelding
Subject: [MW:9821] SA 516 Gr.60 high in manganese-accept or reject

 

Dear all,
                  We have received MTC for SA 516 Gr.60 plate of 10mm thickness with manganese of 1.47%,the lab test also give the same.

is it acceptable as per SA 516 SPEC.

Please confirm shall we accept or reject the plates,we have procured more tonnes of materails & started fabrication?

what shall we do in this stage?

How to overcome this issue ,pls guide

krishna




--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...