Re: [MW:10045] hydro test

Hii

there should be static head pressure difference when line is at
different levels in terms of heights.

For each 10m height , 1 Bar difference is allowabale as per design
calculations ...

It is normal practice for all pipelines ....when you are doing hydrotest ..

Thank you

Suresh

On 2/27/11, k.ilangkumaran ilangkumaran <k.ilangkumaran@yahoo.com> wrote:
> Dear experts,
>
>                Could you explain me that why there is big difference
> pressures between two gauges installed while hydro testing? The first
> pressure gauge shows 3barg less than the one installed in 30meters above.
>
> regards
> Ilan
>
>
>
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>


--
Thanks & Best Regards,

Suresh

Mobile No: 91-92 92 905 905

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...