Thursday, February 10, 2011

[MW:9802] RE: 9798] Backing by gas/Back purging is not essential for P.No 8 - Austenitic stainless steel? - ASME Sec 9

No for Austenitic Steel it is must to do back purging so that oxygen does
not come in contact with molten Chromium as SS is having Cr and during
welding if it is coming in contact with oxygen it will become chromium oxide
and the same is very brittle and lead to weld crack.

With kind regards,
Vinod Kumar Kataria
GM - Operations
Bliss Anand Private Limited,
92B/93B Sector 5
IMT Manesar,Gurgaon,
National Capital Region Delhi.
India .
Phone : +91-124-4366000 (9 Lines)
Mobile Phone : +91-9560199004
Fax : +91-124-2290884

-----Original Message-----
From: materials-welding@googlegroups.com
[mailto:materials-welding@googlegroups.com] On Behalf Of Srinivas Engr
Sent: Thursday, February 10, 2011 12:03 PM
To: Materials & Welding
Subject: [MW:9798] Backing by gas/Back purging is not essential for P.No 8 -
Austentic stainless steel? - ASME Sec 9

Dear All,

As per QW 256, GTAW process,
QW 408 Gas, There is no essential variable for gas Backing for P.No.
-8. Austentic Stainless Steel. A312 & others.
So we can qualify WPS without gas backing/Bsckpurging.
Am i right or not?
Pl clear me

Regards
Srinivas

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and
meant for educational purposes only, Users must take their own decisions
w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...