Hi
Since spec. clearly indicates the range, it has be to within the range, otherwise not acceptable
Thanks & Regards,
K. Babu
----- Original Message -----
From: joshi jaydeepSent: Wednesday, January 19, 2011 11:47 AMSubject: [MW:9317] Higher value of UTS, acceptable?Dear all,I have a material A350 LF2, CL1 with UTS of 724MPa (As mentioned in TC of Manufacturer).As per ASME Sec IIA, requirement is 485 - 655 Mpa.The higher value of UTS beyond the spec requirements is aceptable?Thanks.Regards,JJ--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.