Monday, January 17, 2011

Re: [MW:9259] WPS without consumable insert

With or without filler metal is one parameter
With or without consumable insert is an other parameter
Those two parameters are not linked together
Best regards
Dr Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
HBS Regional Technical Manager


  From: Kisan Gamane [kisankrishna1506@gmail.com]
  Sent: 17/01/2011 11:21 ZE5B
  To: materials-welding@googlegroups.com
  Subject: [MW:9254] WPS without consumable insert


Dear Expert
Please advice me about following.
 
If WPS ( GTAW)  is qualified for  without consumable  insert ; can we use it for with insert.
Code used for acceptance:- ASME sec IX
 
Thanks in advance for ur help.
 
Thanks & regards

--

 

किसन गामणे

नाशिक

After falling twice to conquer the mount

Everest, Edmund Hillary said-
I'll come again and conquer you because as a mountain you can't grow,
but as a human I can..."


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...