Tuesday, January 25, 2011

[MW:9465] RE: 9462] Electrode Vs WPS & PQR

No it is not. Code only requires same F number {QW-404.4} and, if
appropriate, A number {QW-404.5}.

Typically a customer requirement.

John

-----Original Message-----
From: materials-welding@googlegroups.com
[mailto:materials-welding@googlegroups.com] On Behalf Of sn vl
Sent: Tuesday, January 25, 2011 8:36 AM
To: Materials & Welding
Subject: [MW:9462] Electrode Vs WPS & PQR

Hi..

It is Mandatory to USE the same electrode used in PQR , in Production
welds..

Regards
SN

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views
and meant for educational purposes only, Users must take their own
decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...