Wednesday, January 5, 2011

[MW:9093] Regarding batch qualification for EC308L

Dear all,
 
we want to take batch test qualification for EC 308L MIG welding (1.2MM DIA) .Can we know which tests will be applicable for this? also please send all lthe details( such as thickness of base metal ).We also want to carry out impact @-196C for this .Please share information regarding this.
 
Regards
Vinit

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...