Re: [MW:8888] ELECTRODE - Change in AWS classification for weld overlay

Hi Kumar,

If you are qualifying WPS in accordance with ASME sec ix, it does't permit to do so, QW 404.37 is one thing also if you see not (9) of QW-453, Chemical analysis is one of the required tests.

In short, a WPS qualified with 316L for clad layer can be used for 316L clad layer only.


Regards
Manpreet Singh
Welding Engineer




On Wed, 22 Dec 2010 14:13:46 +0530 "Bathula Raghuram (Mumbai - PIPING)" wrote
>

Please read carefully QW404.37, in case of weld overlay AWSclassification will be an essential variable

From:materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] OnBehalf Of Karthik
>Sent: Wednesday, December 22, 2010 10:58 AM
>To: materials-welding@googlegroups.com
>Subject: RE: [MW:8872] ELECTRODE - Change in AWS classification for weldoverlay

E309-L and E316L are both same F number(5) and A number (8),SFA number 5.4. So it is acceptable.

Thanks & Regards,

(Karthik)


> --- On Wed, 12/22/10, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote:


> From: Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com>
> Subject: RE: [MW:8868] ELECTRODE - Change in AWS classification for weld overlay
> To: "'materials-welding@googlegroups.com'" <materials-welding@googlegroups.com>
> Date: Wednesday, December 22, 2010, 12:09 PM

Each AWS classification of A-No. 8 analysis of table QW-442, shall require separate WPS qualification (QW404.37).
>
> -----Original Message-----
> From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of KUMAR
> Sent: Wednesday, December 22, 2010 10:26 AM
> To: materials-welding@googlegroups.com
> Subject: [MW:8866] ELECTRODE
>
> Dear sir,
>
> In weldoverlay smaw process welding, the changing electrode E309L in
> place of E316L is acceptableor not? It mentioned in WPS that E309L
> is for barrier Layer and E316L for clad layer
>
> Thanks and regards
> M.Kumar
>
>
>
>
>
>


--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...