Wednesday, December 22, 2010

Re: [MW:8875] ELECTRODE

Dear Kumar,

I did not understand your question right,

Do You need to change the second layer electrode from E 316L to E 309L or vice versa?

Regards,

Praveen
Sr.Welding Engineer
Muscat

--- On Wed, 12/22/10, KUMAR <kumartkp@gmail.com> wrote:

> From: KUMAR <kumartkp@gmail.com>
> Subject: [MW:8866] ELECTRODE
> To: materials-welding@googlegroups.com
> Date: Wednesday, December 22, 2010, 10:25 AM
> Dear sir,
>
> In weldoverlay  smaw  process welding, the
> changing electrode E309L in
> place of E316L is acceptableor not?  It 
> mentioned in WPS that E309L
> is for barrier Layer and E316L for clad layer
>
> Thanks and regards
> M.Kumar
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members
> personel views and meant for educational purposes only,
> Users must take their own decisions w.r.t. applicable
> code/standard/contract documents.
>


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...