Please read carefully QW404.37, in case of weld overlay AWS classification will be an essential variable
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Karthik
Sent: Wednesday, December 22, 2010 10:58 AM
To: materials-welding@googlegroups.com
Subject: RE: [MW:8872] ELECTRODE - Change in AWS classification for weld overlay
E309-L and E316L are both same F number(5) and A number (8),SFA number 5.4. So it is acceptable. --- On Wed, 12/22/10, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote: From: Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> Subject: RE: [MW:8868] ELECTRODE - Change in AWS classification for weld overlay To: "'materials-welding@googlegroups.com'" <materials-welding@googlegroups.com> Date: Wednesday, December 22, 2010, 12:09 PM Each AWS classification of A-No. 8 analysis of table QW-442, shall require separate WPS qualification (QW404.37). -----Original Message----- From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of KUMAR Sent: Wednesday, December 22, 2010 10:26 AM To: materials-welding@googlegroups.com Subject: [MW:8866] ELECTRODE Dear sir, In weldoverlay smaw process welding, the changing electrode E309L in place of E316L is acceptableor not? It mentioned in WPS that E309L is for barrier Layer and E316L for clad layer Thanks and regards M.Kumar |