Wednesday, December 22, 2010

RE: [MW:8872] ELECTRODE - Change in AWS classification for weld overlay

E309-L and E316L are both same F number(5) and A number (8),SFA number 5.4. So it is acceptable.

Thanks & Regards,

(Karthik)

Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Wed, 12/22/10, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote:

From: Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com>
Subject: RE: [MW:8868] ELECTRODE - Change in AWS classification for weld overlay
To: "'materials-welding@googlegroups.com'" <materials-welding@googlegroups.com>
Date: Wednesday, December 22, 2010, 12:09 PM

Each AWS classification of A-No. 8 analysis of table QW-442, shall require separate WPS qualification (QW404.37).

-----Original Message-----
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of KUMAR
Sent: Wednesday, December 22, 2010 10:26 AM
To: materials-welding@googlegroups.com
Subject: [MW:8866] ELECTRODE

Dear sir,

In weldoverlay  smaw  process welding, the changing electrode E309L in
place of E316L is acceptableor not?  It  mentioned in WPS that E309L
is for barrier Layer and E316L for clad layer

Thanks and regards
M.Kumar


Filtered by Hosted Filtering


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...