Saturday, December 11, 2010

Re: [MW:8691] 13 Chrome & 22 Chrome-Welding & NDT

Dear Karthikeyan,
 
Backing flow rate not mentioned in this WPS format,kindly update me.
thanks Regards
Sujay

On Thu, Dec 9, 2010 at 11:22 AM, Karthik <karthik6684@yahoo.com> wrote:
Hi,
This attached file might be useful to you

Thanks & Regards,

(Karthik)

Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Tue, 12/7/10, Vikas Bhandari <vikas.bhandari349@gmail.com> wrote:

From: Vikas Bhandari <vikas.bhandari349@gmail.com>
Subject: [MW:8572] 13 Chrome & 22 Chrome-Welding & NDT
To: materials-welding@googlegroups.com
Date: Tuesday, December 7, 2010, 8:19 PM


Dear all 

What are the necessary precautions to be taken for welding 13Cr to 13 Cr (martensitic stainless steel), 22Cr to 22 Cr (duplex SS) and 13Cr to 22 Cr.(It would be great if someone can share a WPS for dissimilar welds). 

Thanks & Best regards


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...