Friday, December 10, 2010

Re: [MW:8663] Acceptance criteria in alloys in pmi testing below specified limits

Dear Mr.Prem, Material is v anchor for heater.Kindly suggest? SDM

On 12/9/10, PREM SHANKARDUTT NAUTIYAL <prem_nautiyal@rediffmail.com> wrote:
>
> Hi
>
> What is the material form you are referring to of SS316L: plate, pipe,
> forging,fitting, welds,....... ??
>
> As per that you have to refer relevant standard for acceptance criteria.
>
> Regards
>
> Prem Nautiyal
>
> On Thu, 09 Dec 2010 17:26:35 +0530 wrote
>>Dear All, can u tell me what is the acceptance criteria for the Ni,Cr
>
> & Mo content below specified values in pmi testing in SS316 L
>
> material.And which standard relates to it.How much deviation we can
>
> accept. SDM
>
>
>
>
>
> --
>
> Thanks,
>
> S.D.Mishra
>
> Mob- 09589444897 (M.P./C.G.)
>
> 09766916581 (Maharastra)
>
>
>
> --
>
> To post to this group, send email to materials-welding@googlegroups.com
>
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
>
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
>
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>
>
>
> PREM S NAUTIYAL
> CELL : 9769316004
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>


--
Thanks,
S.D.Mishra
Mob- 09589444897 (M.P./C.G.)
09766916581 (Maharastra)

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...