Wednesday, December 8, 2010

Re: [MW:8615] tempering of plates

Hi!
What is the delivery condition of Gr11 plate  i) is it NR + Tempering or ii)NR +ACC cooling + Tempering
In case of condition ii) you can not leave with only  Tempering after Hot forming , You require to carry out NR + ACC cooling + Tempering after hot forming
Incase of condition i) you can go for tempering after hot forming with temperature range of NR
However you need to ask for simulated heat treatment condition form plate mfgr
In my openion why not to get the D/E with crown and petal and not single piece
Regards
Hegde p.B.


From: asad azmi <azmiasadayub@gmail.com>
To: materials-welding@googlegroups.com
Sent: Wed, 8 December, 2010 6:47:01 PM
Subject: [MW:8604] tempering of plates

Dear All,
 
Greetings.
 
A vessel is to be fabricated as per ASME SEC VIII DIV 1 for data as below-
 
Plate Material  -  SA 387 GR 12 CL2  ,   80 THK.
 
Plate is to be used for dished head. as per the  ASME SEC IIA  normalizing and tempering is required for the plate.
 
forming of Dished head will be  by hot forming.
 
during reveiw of MTC it was observed that Tempering temeprature was not meeting the requirement.therefore re - tempering is required for the plate.
 
My question is whether re - tempering is required for the plate OR it can be done after Hot Forming of dished head.
 
As per the requirment after hot forming, dished head will under go Normalizing and tempering.
 
Pls suggest.
 
Thanks in advance for your valuable suggestions.
 
Regards
 
Asad Azmi
 
 
 
 
 
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...