Tuesday, December 7, 2010

Re: [MW:8564] phased array vs. RT

Good morning Mr.Navid,
ASME have code case 2235 ,this code case saying we can use recordable UT in replace  of RT,
& phase array is a recordable UT,so for me it is acceptable.but please take advice form AI if the vessel is code stamp.

please refer code-case 2235 latest revision.


--
Thanks & Regards.

Santosh Gaikwad

Material Testing & Inspection Services(MTIS),
Surat,India.



On Tue, Dec 7, 2010 at 9:00 AM, Navid Navidi <navid_751400@yahoo.com> wrote:
Hi all,

is it possible to use phased array technique instead of RT for NDT teast of a pressure vessels.
Does standard allow us to do so?
what is its advantages?

thank you in advance
Saeed

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...