Tuesday, December 7, 2010

Re: [MW:8539] Re: Regarding Repair Calculation

Hi,
The attached file might be useful to you.(per film) i think it is widely use in most companies including ours.

Thanks & Regards,

(Karthik)

Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Mon, 12/6/10, joshi jaydeep <jaydeep.p.joshi@gmail.com> wrote:

From: joshi jaydeep <jaydeep.p.joshi@gmail.com>
Subject: Re: [MW:8525] Re: Regarding Repair Calculation
To: materials-welding@googlegroups.com
Date: Monday, December 6, 2010, 2:40 PM

Repair % would be,
 
15mm (Repaired length) x 250mm (Total Length of seam) / 100= 6%
 
One more method of cauculating repair % is Spot wise.
 i. e % Repair= (No of RT spot repair / Total RT spot )*100
 

Jaydeep Joshi | welding engineer TDW India Limited

Plot No 16 | Phase –III | Alindra – Savli G.I.D.C | Taluka : Savli | Vadodara – 391 775

Board : +91-2667- 619900 | Fax : +91- 2667- 619501| Extension : 7845

E-Mail : jaydeep.joshi@tdwilliamson.com  | www.tdwilliamson.com

Cell: +91 9978959626

P    Before printing, Think about ENVIRONMENTAL responsibility



On Mon, Dec 6, 2010 at 12:20 PM, PBR <pbrerode@gmail.com> wrote:
Dear Raj,
 
I have a doubt, For example in a 10mm thickness job a defect of 5mm length X 3mm width noticed under 5mm depth, for repairing purpose the excavation will be more than the defective length ( approximate of  15mm length & depth 6mm X width 6mm),and also let us keep the total length of NDT completed as 250mm,at this condition what is the repair percentage. Do you will consider the defect area or excavated area,
 
With regards,
 
Balajirajajan.P
 
 
-------Original Message-------
 
From: Raj
Date: 12/5/2010 8:52:12 PM
Subject: [MW:8506] Re: Regarding Repair Calculation
 
Hi,
 
1) Percentage Repair Rate = Defective Length Repaired / Total length
of NDT completed
OR
2) Percentage Repair Rate = Number of joints Repaired / Total number
of joints NDT completed
 
Cheers!
 
Rajasekhar
 
On Dec 1, 4:38 pm, ahmed <Ah...@costaindas.ae> wrote:
> Dear Friends,
>
> I Want to know that how to calculate repair percentage for various diameter
> of pipes, any reference or Para available in Code.
>
> Best Regards,
>
> Shaikh Ahmed . k .
>
>  QA/QC Engineer
>
> COSTAIN ABU DHABI COMPANY.W.L.L
>
> (A division of Costain Oil & Gas Process Limited, Manchester, UK)
> P.O. Box no: 3069
> Abu Dhabi-Das Island
> United Arab Emirates
>
> Mobile:     +971-567090644
> * Tel:      +971-2-6063850 (Ext:216)
>
 
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
FREE Christmas Animations for your email – by IncrediMail! Click Here!

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...