Thursday, December 23, 2010

[MW:8892] WELDING WITH F Nr. 4 ELECTRODE FOR DOUBLE V

Dear All,


From PQR done with E6010(FN 3) as root and E7018 as Hot pass and
capping, can we form WPS with root, hot pass and capping as E7018???

From ASME Sec IX it is clearly given that F Nr.4(E7018) Qualified wth
backing is not qualified to carry out without backing.

In double V grove welding can I form this WPS?? Since the welding on
the second side is provided with backing by the first side weld.??


Regards

Akhil

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...