Re: [MW:8418] SS304 welding

  • ensure proper purging of the weld joint
  • the quality of argon gas in GT AW
  • proper shielding of job


regards




On Sat, Nov 27, 2010 at 8:40 PM, Mayur Purwant <mayur_purwant@yahoo.co.in> wrote:
pl advise,
 
I am Facing problem in SS304L welding,
 
The job requirement is,
Welding of SS304  12mm thk plates with SS308L filler wire i.e. TIG120 (GTAW only) in 3G position and the RT of the joint is as per sec III.
 
When I did welding, I found Clusters and Porosity in RT film, I did trials for the same on 200 mm length coupon with same thk base material and it found OK in RT.
 
Again I decided to weld job with puting same parameters as per mock up, But surprisingly in RT film again the same problem was observed i.e. clusters and porosity.
 
Please advise me hoe to minimise or reduce this problem. 
 
 
Regards,
Mayur

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...