Friday, November 19, 2010

Re: [MW:8328] difference btw class 1 & class 2 material-reg

Minimum UTS will vary for class 1 and class 2. For exanmple class 1 may be 60ksi min and class 2 may have 75 ksi min uts.
vanchi

On Sun, Nov 14, 2010 at 10:09 AM, siva chidambaram <mechsivachidambaram@gmail.com> wrote:
Dear all,

Greeting

I've a doubt that, how can to differentiate between SA 387 Gr22 Cl1 material with SA 387 Gr.22 Cl2 material.

M. Sivachidambaram
Welding Engineer

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...