Re: [MW:8218] PQR mentioning position 3G and our WPS stated 1G

Dear zul,

As per ASME sec. IX, The addition of position is a non essential variable, also change in position is supplementary variable. If your PQR doesn't have impact test, you may use the same WPS, You need not to go for a new PQR.

Hope you understand the summary.

M.Sivachidambaram
+919597165173



On Thu, Nov 11, 2010 at 3:05 PM, Zulfan <zulfan@insing.com> wrote:
Dear all,
 
please advice in our PQR mentioning position 3G and our WPS stated 1G
is the WPS able to apply or need to run again PQR again?
code ASME sec IX
 
Thank
zul

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...