Thank you all for your inputs,

 We have written a technical clarification to client about the details and knowhow reason for the use of this material against the said service, however we have decided to go with the Hastelloy C276 for these services.

We have also contacted Nihon Yakin of Japan, but presumably they have obsolete this alloy and are offering higher grade equivalent to Hastelloy C276..

Will put the same when I receive  the inputs from the Vendor and client.

Thank you once again.

 

===================
Bagesh Kumar
Seoul 135985
===================

 

 

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Stefan SAUCIUR
Sent: Friday, November 05, 2010 11:23 PM
To: materials-welding@googlegroups.com
Subject: Re: [MW:8098] (NAS144M) equivalent of this material??

 

Please find this on

 

 

Best regards,

Stefan

--- On Fri, 11/5/10, Harish Kannepalli <harishkannepalli@gmail.com> wrote:


From: Harish Kannepalli <harishkannepalli@gmail.com>
Subject: Re: [MW:8086] (NAS144M) equivalent of this material??
To: materials-welding@googlegroups.com
Date: Friday, November 5, 2010, 12:57 PM

Dear Mr. Bagesh,

                           Thank you for introducing some new material to me as well as group. This material is a patented one almost equivalent to 316L. Please find the link attached for further info.

http://ip.com/pdf/patent/US6966973.pdf

2010/11/5 Bagesh <bagesh.kmr@gmail.com>

Hello there,

                  I have been doing a project in Korean peninsula and certainly while browsing through the piping material specification I have found NAS144M material and it has been used for the service of ACRYLIC ACID, REACTED GAS and ESTERS. The P T Rating for these services is 150 Rating.

When enquired with vendors they dont have any clue until we supply the correct material property, the contract MSD has shown 254SMO as the property of this material,

For the reference we have used SS316L for such services in other projects, but the client have rejected our request and they just resist on the material property,

Could any one have some brief on the said subject or equivalent ASTM spec or Its UNS no..

I do not have any other things to share on the same.

Regards

===================
Bagesh Kumar

Seoul 135985

===================

 

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.




--

regards,

Harish.

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...