Good morning gentlemans,
We had a WQT with ASME IX, P1 to P1 material with the thickness of 18.56mm x 6'' pipe.
 According contractor the welder is qualified in (QW-402)P-No1 through 15F,P No34, & PNo.41 through PNo.49.
In my view ,material range should be as per QW423. Please correct me
--
suresh

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...