Sunday, October 17, 2010

Re: [MW:7610] Welding of A312 Gr.TP321H

no need to requalify
vanchi

On Sun, Oct 17, 2010 at 12:43 PM, ARUN KUMAR <arunku72@hotmail.com> wrote:
Dear All,
 
I need your valuable advice on following.
 
I need to carry out the welding of A312 Gr. TP321 H ( GTAW process) with a WPS qualified for P8- P8 material. In the WPS it is mentioned that to use ER 347 H for welding A312 Gr.TP321 H.
 
In ASME, section II, there is no F no classification for ER 347 H ( other filler ER308 H & ER316 H are classified in 5.9)
 
The filler wire is supplied by ESAB and theire Material cert is showing only ER 347 ( SFA 5.9) with carbon % .04 ( As per section II ,Carbon % for ER 347 is max .08%)
 
Since there is difference in C %, do I need to requalify the WPS using  the above filler ( ER 347 with C % .04)?
 
Thanks and regards,
 
Arun

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34832] Inquiry about Single Bevel with Back Grinding

Dear Uday, As per your question that one is called with backing only,Simple both side you are welding it is backing with strip or without st...