On Thu, Sep 23, 2010 at 12:49 PM, limesh M <limesh78@gmail.com> wrote:
 
 
What are all the NDT applicable on GRE/GRV/GRP Pipes and joints other than Barcol Hardness test?
 Though it is a composite,UT,X-Ray,Acoustical emission,Thermography are possible.
Ultrasonic thickness gauging is possible or not in GRV/GRE/GRP pipes?
 Yes
Is there any mill certificate/Composition certificate available with GRV/GRE/GRP pipes from manufacturer?
 As per my knowledge, No.You can find labels with pipe number which is attached/laminated to the outside/inside pipe body. Manufacturer can easily change it according to their convenience !!!
Is the pipe material composition variying according to manufacturer?
 As per my knowledge,Yes. Resin ,Hardner,Glass mixture vary according to manufacturer.
Is there any world standard for GRE/GRV/GRP pipe material traceability?
 As per my knowledge,No.You can get recipes from the manufacturer.
Is it true that the debris coming out from GRE/GRV/GRP pipes during fabrication are highly dangerous to human health?
 Yes,the debris contains glass,which may harm human lungs and respiratory system if inhaled.
Is it true that the fumes coming out from resin and hardner during lamination are highly dangerous to human health?
 Yes,direct exposure to this fumes is dangerous.
 
 --
Welder's Helper
 
Never bend my head infront of anyone other than GOD the almighty.
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.




--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...