Friday, October 8, 2010

Re: [MW:7455] Duplex Wire

Dear larry,
T0 wire is meant for downhand welding and horizontal fillets whereas T1 wire is meant for all positional welding.
-1 is for Co2 gas shielding  and -4 for mix gas Ar+ Co2 shielding
vanchi

On Fri, Oct 8, 2010 at 7:24 AM, Larry <quality@unieng.com.au> wrote:

Hi There,

 

What's the difference between E2209T0-4/-1 and E2209T1-4/-1?

 

 

Thanks in advance to all.

 

 

 

Cheers,

 

Larry

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...