Hi, You are correct. As per CENISO/TR 20173:2005(D) ,SA352 LCB is fall in Group number 1.1 and TP316 fall in Group number 8.1. According to ISO15614,Group number 1 with Gr.No.1 qualified for 1 with 1.Also Gr.No.8 with Gr.* qualified for 8 with 8.If you want to weld Group number 8 with Group number 1,WPS and PQR shall be qualified with any one of following group number combination. According to ISO15614-1,Table-3 Group number 8 with Group number 2 - qualified for 8-2,1 Group number 8 with Group number 3 qualified for 8-3,2,1 Group number 8 with Group number 4 qualified for 8-5,4,2,1,6.1,6.2 Group number 8 with Group number 5 qualified for 8-5,4,2,1,6.1,6.2 Group number 8 with Group number 6 qualified for 8-6,4,2,1 So the WPS shall be qualified with anyone of the above combination to weld SA352 LCB(Gr.1.1) with TP316(Gr.8.1) Thanks & Regards, (Karthik) Karthikeyan.S QA/QC Manager Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282 --- On Wed, 10/6/10, parviz farhadi <parvizfarhadi@gmail.com> wrote:
|
--