John

 

Without going into detail in this mail it is my experience over years in the desalination and power industry with heat exchangers we must carry out the welding BEFORE expanding.

 

To ease this activity as the tubes will be loose in the tubeplate we would lightly expand only initially to snug the wall onto the plate – we then seal weld or revere weld depending on the pressure application.

 

After the welding we can fully expand as intended.

 

Ref the expansion activity – We can only assess the required torque ranges and wall reduction requirements by carrying out pull off / push off tests – we keep the wall reductions low to avoid cracking – accompanied by a detailed expansion method statement for the work.

 

Can we also assume the tube entry side has a taper?

 

Mail me if I can assist any more.

 

 

Archie Clubb

Fabrication Specialist & Vessel Design.

VWS Westgarth Ltd

Archie.clubb@veoliawater.com

 

 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of John Hardcastle
Sent: 13 October 2010 11:02
To: materials-welding@googlegroups.com
Subject: [MW:7532] Expanding Alloy 20 Tubes

 


We are going to use Alloy 20 tubes in a heat exchanger,we will expand approx 200 mm length into grooves and then seal weld.
We have been told expansion is difficult, has anyone had any experience of this procedure.

John Hardcastle

 

Fabrication Manager

 


Euro Mechanical Contractors Company Factory

P.O. Box 46153
Abu Dhabi
United Arab Emirates

 

Phone: +971 2 550 08 99

Fax: +971 2 5501898

Mobile: +971 50 4445873

 

Email: jhardcastle@euromechanical.com

www.euromechanical.com


 

This email is intended for the addressee(s) only, and may contain confidential or privileged information. Unauthorised use of this information, or distribution, copying or other dissemination is strictly prohibited.

If you have received this email in error, please destroy it immediately.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

***************************************************************************************************************************************************************************
This e-mail (which includes any files attached to it), it is intended solely for the named recipient and may contain CONFIDENTIAL, legally privileged or trade
secret information protected by law. It has been sent it via the internet and is therefore not secure against corruption, interception or unauthorised modification.

If you are not the intended recipient please do not read, use, disclose, distribute, copy, print or rely on any information contained in this e-mail. Please
immediately notify us by telephoning +44 (0) 1494 887808 or return it to us by e-mail to the sender, confirming that this e-mail has been deleted from
your system and any hard copies destroyed.

To the extent permitted by law, neither we nor any of our subsidiaries, parent entities or other affiliates, nor any employee, director or officer thereof,
accepts any liability whatsoever in relation to this e-mail including liability arising from any external breach of security or confidentiality or for virus
infection or for statements made which are clearly the sender's own and not made on our behalf.

"We" and "our" in this footer refer to the following legal entity:

VWS Westgarth Ltd. Registered in Scotland No. 147604, Orbital House, 3 Redwood Crescent, East Kilbride, G74 5PR

This company is a member of the Veolia Water Solutions & Technologies group, but please contact the sender should you have any question
regarding the legal entity on whose behalf this email was sent.
***************************************************************************************************************************************************************************

 ************************************************************************* This e-mail message and any attachments to it are intended only for the  named recipients and may contain confidential information. If you are not one of the intended recipients, please do not duplicate or forward this e-mail message and immediately delete it from your computer. If you  received this email in error, please notify postmaster@veoliawater.com *************************************************************************       

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...