[MW:7420] Dial indicating pressure gages - Range for hydro testing

Since this posting does not contain a meaningful subject line hence was not posted in the group, instead I am directly replying with changing the subject line. Members are requested to take care hence forth.

 

Dial indicating pressure gages used in testing shall be graduated over a range of about double the intended maximum test pressure, but in no case shall the range be less than 11⁄2 nor more than 4 times that pressure. Digital reading pressure gages having a wider range of pressure may be used provided the readings give the same or greater degree of accuracy as obtained with dial pressure gages (UG102(b) for Sec VIII div 1 vessels).

 

And many of the company standards indicate this requirement, for e.g. ARAMCO specifies

"The gauges must have a range such that the pressure specified for the test is between 30% and 80% of the full range".

 

From: Nachhattar Singh [mailto:n.singh@moodyint.com]
Sent: Thursday, October 07, 2010 1:46 PM
To: materials-welding@googlegroups.com
Subject: RE: [MW:7407] difference between tightening test and tightness test in piping work.

 

Dear All

 

Can you please confirm as to which standard / code call for a Pressure gauge rating to be 2 times the test pressure of the equipment .

 

The second question is what do you mean by  the term   Mil

 

Thanks and regards

 

 


Nachhattar Singh

Director

Phone: 91-22-42333600 Extn :624 - +  91-98201 81158

Fax:+  91-22-42333607

Email:n.singh@moodyint.com

Web: www.moodyint.com

Web: www.edn.com.au

Web: www.petrospect.com

Web: www.pro-inspect.com

Moody International (I) Pvt Ltd

406-410, NAVKAR CHAMBERS, 'B'Wing
Marol Naka , Andheri-Kurla Road ,
Andheri ( E ) ,

Mumbai

Maharashtra

400 059

India

 

RSTS & EDN are wholly owned subsidiaries of

Moody International and are leaders in

HSE Consulting and Training

 

 Moody Group Confidentiality Note:  The information transmitted is intended only for the person(s) or entity to which it is addressed.  It may contain confidential and/or privileged information or material.  Any review, retransmission, dissemination to other use of, or taking of any action in reliance upon this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any computer.

 

__________


No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...