Sunday, September 26, 2010

Re: [MW:7206] Heat treatment Butt joint of SA-210 Gr.A1 and SA-312 TP 304H

Dear Sudharsan S,
 
This particular joint is one of the joint from the heat recovery steam generator (unfired) constructed as per ASME Section VIII Div.1. As per UW-2 (c) this particular steam generator needs to be heat treated.
Thickness involved 12.7 mm.
In my opinion there should not be any problem for the SS material like carbide precipitation.
Please suggest the heat cycle.
 
Thanks in advance.
Regards
Shinde
----- Original Message -----
Sent: Sunday, September 26, 2010 1:55 PM
Subject: Re: [MW:7199] Heat treatment Butt joint of SA-210 Gr.A1 and SA-312 TP 304H

Shinde,
 
SA 210 Gr A1 is a seamless medium carbon (0.27% max) steel tubes. If you weld this to SA 312 TP 304H (18% Cr 8% Ni) with fully austenitic electrode like AWS E/ER 309LMo, from metallurgical point of view , there is no need for PWHT.
 
Can you just tell me why you need PWHT, is it from process point of view or for any other reason? What is the thickness as well.
 
On Fri, Sep 24, 2010 at 6:25 PM, agstes <agstes@gmail.com> wrote:
Dear All,
 
I want to know the post weld heat treatment procedure/cycle for the butt joint of SA-210 Gr.A1 (P1) and SA-312 TP 304H (P8).
 
Thanks in advance.
 
Shinde A.G.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...