Friday, September 24, 2010

Re: [MW:7184] EFFECT OF GAS MIXTURE ON DELTA FERRITE

Dear Bhavesh,
309L mo welding consumable may contain 12to 15% ferrite but barrier layer will have low ferrite due to dilution from carbon steel particularly due to increase of carbon in barrier layer.
vanchi
On Fri, Sep 24, 2010 at 4:04 PM, JIGO <bhaveshpatel.me@gmail.com> wrote:
Dear All,

Generally after barrier layer with SS309LMo we have got more than 10 %
ferrite but with following condition mentioned below i have got
ferrite content in between 1.8 ~ 3.8 FN.


Process : FCAW
Layer : Barrier Layer
Consumable : E309MoLT0-1
Gas : Argon(80%) + CO2 (20%)

Current : 200 - 215 Amp
Voltage : 30 - 32
Speed : 250 mm/min.


Kindly share what should be the reason behind the same.

Regards,
Bhavesh

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...