Hardox weld should be used using soft electrodes.(Yield Strength Less than 500N/mm2).If your weld subjested to heavy wear it is recommended to use the hard facing electrode for the cap beads. Hardox is weldable using the following electrodes. SMAW - E7018/E7028/E8016 SAW - F7Ax-xx MIG/MAG - ER70-x FCAW - E7xT-x Hardox 400 40mm combined thickness will need 75°C preheat and the interpass temp should be kept to 150 - 175°C. If preheating is a problem it is possible to weld without preheat using a 309L type electrode or wire, but remember stainless cannot be burned with standard oxy-acetylene. Thanks & Regards, (Karthik) Karthikeyan.S QA/QC Manager Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282 --- On Thu, 9/23/10, kamaleshwar sahu <kamaleshwar.sahu@beekaycorp.com> wrote:
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.