Re: [MW:7079] F-No&A-No of ERNiCrMo-3

For ERNiCrMo-3 Fnumber is 43, please recheck WPS if they have specified some other filler such as NiFeCr-1, NiCrMo-9 falls under F45.
A Numbers are not applicable for non ferrous welds

No such condition as for P number/F Number should be same in Sec IX.

On Sat, Sep 18, 2010 at 6:38 PM, limesh M <limesh78@gmail.com> wrote:
Dear All,
 
I want to prepare a WPS for ,
 
material ASTM B 423 (P No-45).
 
Process - GTAW
Construction Code - ASME B31.3
Welding Code - ASME BPV SEC IX
 
What is the F - No. of ERNiCrMo-3?  43 or 45?One of the  WPS in my hand says 45 !!!
I have reviewed ASME BPV SEC IX QW 432,F-No. section and found that 43.Now I need clarification from experts,which one is correct 43 or 45?
 
What is the A - No. of ERNiCrMo-3? I have reviewed QW 422 A-Numbers section,but couldn't find.
 
Is there any condition that P- no. and F- no. shall be same?
 
Seniors, I need your help on this issue.
 
 
Regards,
 
Limesh

--