Quench in water to bring down to temp. 350 degree Centigrade within 3 minutes (max)
Regards,
Sachin A Kavathekar
From:
Sent: Friday, September 03, 2010 10:57 AM
To:
Subject: RE: [MW:6837] Stabilized heat treatment
No cooling media required, after soaking remove insulation and let it cool in air.
From:
Sent: Friday, September 03, 2010 10:51 AM
To:
Subject: [MW:6836] Stabilized heat treatment
Dear Members
What shall be the cooling media for Stabilized heat treatment for grades like SS321, SS347 etc. as per code it is only mentioned that soaking temp. 900 deg.C / soaking time 4 hours.
Regards
Subrata Das
No comments: