On Thu, Aug 12, 2010 at 2:08 PM, venkat ramana <venkatgps.ramana@gmail.com> wrote:
Dear All,Please let me know with reference, query is A repair organization has a WPS which states it is qualified for P-8 to P-8 material welded with E308, E308L, E309, E316, electrodes (SMAW proess). The PQR, supporting this WPS, states the weld test coupon were SA-240 Type 304L material, welded with E308 electrodes. Is the WPS properly qualified for the base material listed?Thanks & RegardsVenkat (QA/QC)--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--