Wednesday, August 11, 2010

Re: [MW:6439] OK 10.71

Hi,

You have to use the same brand which is used for PQR. It is essential variable. Check the product catalog.

Thanks & Regards
Muhammed Ibrahim PK



On 11 August 2010 14:00, Eng/ Mostafa Kamel Hussein <mkh_200@yahoo.com> wrote:
Dear all
I have a flux with name of SA AB 1 87 AC H5. What is its name in the WPS based on ASME IX qualification. put in your mind that its AWS name is     F7A4-EM12K and you know that this name include the flux and the electrode so what i need is the name of flux only in ASME designation
Is OK 10.71 suitable for this flux as this designation is the nearest for the flux i used? put also in your mind that this flux SA AB 1 87 AC H5 doesn't exit in ESAB handbook 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...