Tuesday, August 24, 2010

[MW:6668] RE: 6623] Manufacturer PQR Test results of 25 Cr 35 Ni to SA 479 TYP 304H - furnace tubes

Hi,

 

The following 25 Cr 35 Ni belongs to which ASTM number and specification.

 

Regards,

Prasanna.R.U.

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Mohamed Abdul Kareem
Sent: 22 August 2010 14:50
To: materials-welding@googlegroups.com
Subject: [MW:6623] Manufacturer PQR Test results of 25 Cr 35 Ni to SA 479 TYP 304H - furnace tubes

 

Hi,

 

Manufacturer PQR Test results of 25 Cr 35 Ni to SA 479 TYP 304H - furnace tubes

 

Tensile test of the 13 mm thick specimen results in 2.67 % & 3.7 % elongation

 

Bend test (As per ASME IX) failed at the HAZ. Manufacturer has followed ASTM A 488 “Standard specifications for steel castings, Welding, Qualification of procedures and personnel” to qualify the procedure.

 

Question

 

 

1.       Is the PQR qualified if QW-466.19 [General notes (E)] is followed?.

 

 

”QW-466.19 - For material with less than 3 % elongation, a macro etch specimen shall be used in lieu of bend test at each bend location. Acceptance criteria shall be in accordance with QW-183(a)”.

 

2.       Can ASTM A 488-8.2.4 be followed to qualify a procedure?

 

“ASTM A 488-8.2.4 – Where the ductility of the parent metal is such as to render it incapable of meeting the bend test requirements, the bend test shall be conducted in the following manner: A bend bar comprised of parent metal heat treated to the ductility & strength requirements of the applicable specifications shall be bent to failure. The side bend specimen shall be then capable of being bent to within 5° of the angle thus determined.”

 

Regards,

kareem

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

 

__________ Information from ESET NOD32 Antivirus, version of virus signature database 5383 (20100820) __________

 

The message was checked by ESET NOD32 Antivirus.

 

http://www.eset.com

 

__________ Information from ESET NOD32 Antivirus, version of virus signature database 5386 (20100822) __________

 

The message was checked by ESET NOD32 Antivirus.

 

http://www.eset.com



__________ Information from ESET NOD32 Antivirus, version of virus signature database 5386 (20100822) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com



__________ Information from ESET NOD32 Antivirus, version of virus signature database 5386 (20100822) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...