It should be penetrameter, and the term penetrameter no longer used in Article 2 of ASME Section V now it is being referred as image quality indicator (IQI). You can select the IQI material from the less radiation absorbing material out of this two (material group 1, CS or SS will do).


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of subrata das
Sent: Monday, August 16, 2010 12:59 PM
To: materials-welding@googlegroups.com
Subject: [MW:6511] Pentameter selection

Dear All

What type of Pentameter should i use during Radiography Test of a butt weld joint of 50 mm diameter & 12 mm thickness and joint between A182 F91(WN Flange) to SB622 UNS N10276(Pipe).

 