Tuesday, July 20, 2010

[MW:6033] Max Interpass temperature in AWS D1.1

Dear Members,

 

Can Anyone tell what is the maximum Inter pass temperature to be maintained

 

for welding an 25 thk plate when impact requirement is specified as Per AWS D1.1.

 

and what is the Minimum Preheat Temperature for the same.

 

 

Thanks & Regards,

Shashi Kumar



Please don't print this e-mail unless you really need to.
*******************************************************************
This e-mail is confidential. It may also be legally privileged. If you are not the addressee you may not copy, forward, disclose or use any part of it. If you have received this message in error, please delete it and all copies from your system and notify the sender immediately by return e-mail. Internet communications cannot be guaranteed to be timely, secure, error or virus-free. The sender does not accept liability for any errors or omissions.
*******************************************************************
"SAVE PAPER - THINK BEFORE YOU PRINT!"

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...