Re: [MW:5696] Using E6010+E6018 for SA 333 Gr.3

Dear Dhinesh,
 
SA 333 Gr.3 ( 3.5 Ni alloy steel) is  low temperature steel  used upto - 100 C which comes under P 9 group and electrode used shall be E 8018 C2.   E 6013 and E 6018 are not at all suibtable for welding of the above material.
 
regards.

N.V. PRASAD
WELDING ENGINEER
VELOSI CERTIFICATION
On Mon, Jun 21, 2010 at 1:25 PM, dhinesh <dhineshsir@gmail.com> wrote:
Dear All,

        I would like to understand what are the causes appear if you
weld the material SA 333 Gr.3 using the electrodes E6010 + E6018. I
any possibilities these electrodes acceptable to weld SA 333 Gr.3.

Regards,

DHINESH

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...