Monday, June 21, 2010

Re: [MW:5682] weld SA-106 to 9 Cr materials P No 5B gr 1 or gr 2

dear ahmed
yes,by using ER 90S-B9(GTAW)&E9018-B9 (SMAW) or E 9015-B9
the joint should be heat treated acc .to ASME B31.3

 
H.KASHKOUSHA



From: Ahmed Hafez <diesel2002@hotmail.com>
To: Welding Material <materials-welding@googlegroups.com>
Sent: Mon, June 21, 2010 1:42:17 PM
Subject: [MW:5681] weld SA-106 to 9 Cr materials P No 5B gr 1 or gr 2

good morning every one
is it applicable to weld SA-106 to 9 Cr materials P No 5B gr 1 or gr 2
 
thanks and best regard


Your E-mail and More On-the-Go. Get Windows Live Hotmail Free. Sign up now.

--