Wednesday, June 16, 2010

Re: [MW:5613] structures acceptance criteria for loss of thickness

Austin,
May I know what is application of structure?
Regards.
JohnR

On Wed, 16 Jun 2010 08:53:04 +0530 wrote
>Dear colleagues, I have a query them.
>
>For the inspection of tubular structures (section square or rectangular), which is the acceptance criteria for loss of thickness and standard that applies? . This structure is 12 years old, made in the open.
>
>Many would know thank
>
>Greetings,
Agustin
>
>











--
>
To post to this group, send email to materials-welding@googlegroups.com
>
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
>
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>



John Rodrigues

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...