Tuesday, June 15, 2010

RE: [MW:5594] NONESSENTIAL OR SUPPLEMETARY

In general The WPS shall state Non essential variables too, however requalification is not required {refer QW200.1(b): contents of WPS, it shall state all types of variables, not only essential, many assume that only essential variable are required to be stated on WPS, it is not correct}
For e.g. the variables stated below are required to be stated on WPS (current/polarity, multi/single pass etc.) in all cases and this range can be modified depending on your weld geometry, position etc. and no requalification is required, when impact test are not required.
However same will become essential, when impact test are required and requalification is necessary, when there is a change on WPS for these variables..

For e.g. Change in Current/polarity (QW 409.4), if not listed under non essential, and not specified on WPS, how the welder/operator will know?

I hope, have clarified your point!

-----Original Message-----
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of ali asghari
Sent: Monday, June 14, 2010 9:05 PM
To: materials-welding@googlegroups.com
Subject: Re: [MW:5592] NONESSENTIAL OR SUPPLEMETARY

yes , it is true.
but my intention is QW409.4 OR QW410.9 OR QW 410.10 are supplementary& non essential in same time.if the impact test isn't required, the supplementary are non essential.why botn of them are marked for the above variables?
how them used?
regard


On 6/14/10, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote:
> Supplementary essential variables shall become mandatory when impact
> testing is required by design. and when there is a change
> requalification is required.
>
> Non Essential variables may be revised on WPS, but requalification is
> not necessary.
>
> ________________________________
> From: materials-welding@googlegroups.com
> [mailto:materials-welding@googlegroups.com] On Behalf Of Ali Asghari
> Sent: Sunday, June 13, 2010 10:46 PM
> To: materials-welding@googlegroups.com
> Subject: [MW:5580] NONESSENTIAL OR SUPPLEMETARY
>
> Dear All
> in QW 250-QW280 in ASME sec IX,SOME VARIABLES ARE NON ESSENTIAL &
> SUPPLEMENTARY IN SAME TIME.e.g in current WHICH ONE SHALL BE
> CONSIDERED?HOW INTERPRETED?
> REGARD ADVANCES

Filtered by Hosted Filtering


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...